If you want to swap roles between the members of a failover pair, you can manually initiate a failover. Within about five minutes after initiating a manual failover, the secondary system assumes the primary role and takes ownership of the VIP address. Note that a manually initiated failover causes a temporary service disruption.

To initiate a manual failover using the GUI, complete the following:

1. Log in to the primary system using your username and password.
2. Go to the **Settings** icon > **Setup** > **Failover** **Configuration** tab.
3. On the **Failover** **Configuration** page, click **Become** **Secondary**.

To initiate a manual failover using the NetMRI administrative shell, perform one of the following:

- Log in to the administrative shell on the primary system and run the `failover role secondary` command.
- Log in to the administrative shell on the secondary system and run the `failover role primary` command.