title: "Installing and Deploying the NetMRI Operations Center"
canonical: "https://docs.infoblox.com/space/NMRI743AG/27984002/Installing%20and%20Deploying%20the%20NetMRI%20Operations%20Center"
format: markdown
---
The NetMRI Operations Center provides a superset of NetMRI discovery and device management, that scales a distributed network management platform up to larger networks and larger deployments. You dedicate satellite NetMRI appliances, called *collectors*, to the tasks of device discovery and device management. You use a central Operations Center appliance to aggregate and view all data collected from the collector appliances, to view the operating state and manage configurations for all discovered network infrastructure devices and discovered IP networks, including routers, firewalls, load balancers, Ethernet L2/L3 switches, end hosts and end host networks, and much more. NetMRI Operations Center makes it easier to manage, control and secure the enterprise network.

Installation of Operations Center Controller appliances changes in Release 6.9. For initial appliance setup, you run the following sequence of Admin Shell commands on the Operations Center appliance from the NetMRI command line:

`configure server license `

`configure server`

`configure tunserver`

For each Collector appliance in your deployment, the command sequence is as follows:

`configure server `

`license `

`register`

See the following procedures to install and deploy your NetMRI Operations Center appliances:

- <span style="color: #0000ff">[*1st*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)<span style="color: #0000ff">[*Step:*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)<span style="color: #0000ff">[*Configuring*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)<span style="color: #0000ff">[*Basic*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)<span style="color: #0000ff">[*Settings*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)<span style="color: #0000ff">[*for*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)<span style="color: #0000ff">[*the*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)<span style="color: #0000ff">[*Operations*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)<span style="color: #0000ff">[*Center*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)<span style="color: #0000ff">[*Controller*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>* *
- <span style="color: #0000ff">[*2nd*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)<span style="color: #0000ff">[*Step:*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)<span style="color: #0000ff">[*Installing*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)<span style="color: #0000ff">[*the*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)<span style="color: #0000ff">[*Operations*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)<span style="color: #0000ff">[*Center*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)<span style="color: #0000ff">[*License*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)<span style="color: #0000ff">[*on*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)<span style="color: #0000ff">[*the*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)<span style="color: #0000ff">[*Controller*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>* *
- <span style="color: #0000ff">[*3rd*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)<span style="color: #0000ff">[*Step:*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)<span style="color: #0000ff">[*Running*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)<span style="color: #0000ff">[*Configure*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)<span style="color: #0000ff">[*Tunserver*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)<span style="color: #0000ff">[*on*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)<span style="color: #0000ff">[*the*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)<span style="color: #0000ff">[*Controller*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>
- *<span style="color: #0000ff">[4th](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)*<span style="color: #0000ff">[Step:](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)*<span style="color: #0000ff">[Installation](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)*<span style="color: #0000ff">[for](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)*<span style="color: #0000ff">[Operations](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)*<span style="color: #0000ff">[Center](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)*<span style="color: #0000ff">[Collectors](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)</span>*
- *<span style="color: #0000ff">[5th](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)*<span style="color: #0000ff">[Step:](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)*<span style="color: #0000ff">[Installing](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)*<span style="color: #0000ff">[the](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)*<span style="color: #0000ff">[Operations](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)*<span style="color: #0000ff">[Center](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)*<span style="color: #0000ff">[Collector](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)*<span style="color: #0000ff">[License(s)](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*
- *<span style="color: #0000ff">[6th](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)*<span style="color: #0000ff">[Step:](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)*<span style="color: #0000ff">[Registering](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)*<span style="color: #0000ff">[NetMRI](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)*<span style="color: #0000ff">[Collectors](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)</span>*
- *<span style="color: #0000ff">[Configuring](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)*<span style="color: #0000ff">[Network](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)*<span style="color: #0000ff">[Interfaces](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)*<span style="color: #0000ff">[for](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)*<span style="color: #0000ff">[Operations](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)*<span style="color: #0000ff">[Center](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)</span>*

# > Macro (anchor)

> Macro (anchor)

Operations Center Appliances and Requirements

You can use the NetMRI Operations Center on physical or virtual NetMRI appliances.

Infoblox offers NetMRI appliances in several models:

- **NetMRI-1102-A** (Discontinued–NetMRI 1102-A appliances may operate as collectors only)

NetMRI-1102-A appliances are equipped with two Ethernet ports, labeled MGMT and SCAN. The MGMT port may be used singly as a dedicated management port for the appliance or may operate as the only active port, carrying both management and network monitoring traffic. By default, the appliance is configured to use the MGMT port for both system administration and network analysis functions.

- **NetMRI NT-4000**

NT-4000 appliances are a next-generation 2U appliance that supports a larger CPU, memory and storage configuration, along with field-replaceable power supplies and disk drives in a RAID-10 array. The NT-4000 appliance may operate as an Operations Center and as a collector appliance. The appliance is equipped with two active Ethernet ports, labeled LAN1 and MGMT. MGMT connects the NT-4000 appliance to the management network and is used for managing the appliance. The LAN1 port is the primary connection to managed networks. (LAN1 may operate as the only active port, carrying both management and network monitoring traffic.) If activated, LAN2 also connects the appliance to managed networks.

- **NetMRI NT-1400**

The NetMRI NT-1400 is designed for smaller enterprise deployments and for use as a collector for Operations Center deployments. The appliance is equipped with two active Ethernet ports, labeled LAN1 and MGMT. MGMT connects the NT-1400 appliance to the management network and is used for managing the appliance. The LAN1 port is the primary connection to managed networks. (LAN1 may operate as the only active port, carrying both management and network monitoring traffic.) If activated, LAN2 also connects the appliance to managed networks.

- **NetMRI NT-2200**

The NetMRI NT-2200 appliances are higher-capacity and higher-speed appliances that may operate as both Operations Center appliances and as collectors. The appliance is equipped with two active Ethernet ports, labeled LAN1 and MGMT. MGMT connects the NT-2200 appliance to the management network and is used for managing the appliance. The LAN1 port is the primary connection to managed networks. (LAN1 may operate as the only active port, carrying both management and network monitoring traffic.) If activated, LAN2 also connects the appliance to managed networks.

- **NetMRI VM**

A virtual machine version of NetMRI installed in a virtual infrastructure platform. You can use NetMRI VMs as collectors and as an Operations Center. A NetMRI VM performance should be sufficient to handle a required number of devices. For more information on how to ensure this, see [*Benchmarking for the Operations Center*](#InstallingandDeployingtheNetMRIOperationsCenter-BenchmarkingfortheOperationsCenter).

---

**Note:** In the Operations Center context, when an appliance acts as the Operations Center it uses only a single port, which is the MGMT port for the NT-1400, NT-2200 or NT-4000. Collectors may use multiple interfaces for network discovery and management, including 802.1q virtual scan interfaces. Typically, both the LAN1 and LAN2 ports are used in this manner on each Collector appliance. For more information, see *<span style="color: #0000ff">[Configuring](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)</span>* *<span style="color: #0000ff">[Network](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)*<span style="color: #0000ff">[Interfaces](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)*<span style="color: #0000ff">[for](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)*<span style="color: #0000ff">[Operations](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)*<span style="color: #0000ff">[Center](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark909)</span>*.

---

In this document, all hardware models are treated generically and referred to as a "NetMRI appliance." Any currently sold appliance model can operate as a NetMRI Operations Center central node.

Infoblox NetMRI appliances should always be supported by an uninterruptible power supply (UPS) to avoid data corruption problems in cases of power outage.

## > Macro (anchor)

> Macro (anchor)

> Macro (anchor)

> Macro (anchor)

Benchmarking for the Operations Center

A NetMRI VM, whether a collector or an Operations Center, is hardware intensive and requires high performance. If you run or plan to run virtual machines in an Operations Center environment, make sure that your virtual machine hosts successfully conform to the required number of network devices. To do so, download the Infoblox Benchmark tool from the Infoblox Support site at [*<span style="color: #0000ff">https://support.infoblox.com</span>*](https://support.infoblox.com). For more information, also download the *Benchmarking* *Guide* *for* *NetMRI* *7.4.2* from the same location.

For related VM best practices, see *<span style="color: #0000ff">[Virtual](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark893)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark893)*<span style="color: #0000ff">[Machine](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark893)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark893)*<span style="color: #0000ff">[Best](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark893)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark893)*<span style="color: #0000ff">[Practices](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark893)</span>*.

# > Macro (anchor)

> Macro (anchor)

Access Using the Command Line SSH client

Initial connections to the NetMRI Administrative Shell using an SSH command line client to the IP address of the MGMT port require a username as one of the command line parameters, as shown in this example:

`ssh ``–``l admin <system>`

where <system> is the hostname or IP address assigned to NetMRI. At that point, you are prompted for the admin account password, which is the same as that used for the browser interface.

# > Macro (anchor)

> Macro (anchor)

Operational and Deployment Best Practices

When you set up and deploy an Operations Center and its associated collectors, follow some best-practices guidelines to ensure a smooth and effective rollout.

1. *Keep device management levels below the licensed device limits on each collector appliance.*
  - Though you have greater flexibility for network connectivity through using network views, multiple scan interfaces and virtual scan interfaces, these features do not influence the licensing limits and capacities of your appliances.
  - License limits should be defined to allow for organic and anticipated growth of the network. Consult with your Infoblox sales representative for a detailed assessment of your licensing needs.
  - License limits are enforced on each collector appliance in an OC deployment. Your OC design should avoid having excessive numbers of licenses on collectors, which can overwhelm the Operations Center and prevent timely operation.
  - New devices can 'bump' older previously-discovered devices from the license limit.
  - Devices in higher-ranked device groups will be prioritized for licensing. (You can change device group rankings in Settings icon **–>** **Setup** **–>** **Collection** **and** **Groups** **–>** **Groups** tab.)
  - Avoid using device licenses on devices in end-user network segments.
2. *During setup of a new deployment, use the default network view when you define your first discovery ranges to initially discover the network.*
  - An initial network view will be present in a new Operations Center deployment. Initial setup for a new Operations Center deployment automatically creates a default network view, named **Network** **1**, as part of the procedure. This network view is automatically assigned to the Collector appliance's LAN1 port before you perform discovery of the network.
  - When you create your initial discovery ranges, the **Network** **1** network view is automatically assigned to the LAN1 interface on the Collector. This network view represents the global routed network, which is the network that NetMRI will discover that is not reliant on virtual networks to route traffic.
  - When you create your discovery ranges, static IP addresses and Seed Routers (in Settings icon **–>** **Setup** **–>** **Discovery** **Settings** **–>** **Ranges/Static** **IPs/Seed** **Routers**), each range provides a Network View drop-down menu. You select one network view for each discovery setting; however, a network view can work with multiple discovery ranges. A single network view can use all three discovery objects.  
You define network views (under Settings icon **–>** **Setup** **–>** **Network** **Views**) and can assign other networks to those views.
  - For VRF discovery, you do not need to define discovery ranges in the initial rollout. NetMRI will discover VRF-aware devices in its first discovery of the global enterprise network. The system then displays a System Health alert notifying you that unassigned VRFs have been discovered.

*3. Avoid using too many device groups. Target using 50 or fewer Extended device groups. Platform Limits also influence the number of device groups allowable in your system.*

> Macro (legacy-content)

*4. Ensure** reliable** network** connections** between** collectors** and** the** Operations** Center **node*.

> Macro (legacy-content)

*5. Use recommended methods to improve reporting performance for your Operations Center.*

> Macro (legacy-content)

*6. Manage Syslog Traffic.*

> Macro (legacy-content)

## > Macro (anchor)

> Macro (anchor)

Virtual Machine Best Practices

Follow the points below to ensure efficient VM-based Collector operation:

1. *Disable or adjust VM performance monitoring systems for the product.*
  - Because Operations Center VMs tend to be extremely I/O intensive, with continuous 100% CPU utilization, vSphere performance monitoring should be reduced or disabled.
2. *Avoid placing multiple NetMRI instances on the same host.*

Operations Center/NetMRI instances present significant demands on I/O, particularly on virtual machine hosts. Avoid attempting to run Operations Center appliance instances on hosts with other VMs.

> Macro (legacy-content)

*3. In the host, use a high-quality RAID controller.*

> Macro (legacy-content)

*4. Enable Intel VT options in the BIOS of the host system.*

## > Macro (anchor)

> Macro (anchor)

Discovery Best Practices

Follow the points below to ensure effective discovery of the network:

1. *For simplicity, perform discovery in phases.*

- Begin with a small set of devices and ensure your discovery ranges, defined credentials, and seed routers are all correct.
- Ensure that firewall gateways for any networks to be discovered allow discovery traffic through open TCP/UDP ports 161 and 162, to allow SNMP traffic.
- Ensure that your discovery ranges, static IPs and seed routers are associated with their correct network views. For initial discovery, your ranges and other discovery settings can simply be associated with the **Network** **1** network view, which is automatically created during appliance setup and is bound to the SCAN1 port on your Collector appliance. For more information, see *<span style="color: #0000ff">[Configuring](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark99)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark99)*<span style="color: #0000ff">[Network](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark99)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark99)*<span style="color: #0000ff">[Views](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark99)</span>*.
- Avoid defining large Discovery Ranges such as /8 or /16, and avoid defining more than 1000 ranges of any size. However, having a large discovery range and seed routers is a more effective discovery technique than using hundreds of small ranges. (You can change device group rankings in Settings icon **–>** **Setup** **–>** **Discovery** **Settings**). For more information, see *<span style="color: #0000ff">[Configuring](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark115)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark115)*<span style="color: #0000ff">[Discovery](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark115)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark115)*<span style="color: #0000ff">[Ranges](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark115)</span>*.
- For discovery using ping sweeps, avoid attempting ping sweeps of greater than /22 subnets. Ping sweeps use protocols other than ICMP and can incur delays in refreshing previously discovered devices. For information on Smart Subnet ping sweep, see *<span style="color: #0000ff">[Defining](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)*<span style="color: #0000ff">[Group](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)*<span style="color: #0000ff">[Data](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)*<span style="color: #0000ff">[Collection](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)*<span style="color: #0000ff">[Settings](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)</span>*.

*Include End-Host devices and Ethernet segments in discovery ranges.*

- Use the **Exclude** **From** **Management** setting on end-host segment discovery ranges to prevent unnecessary SNMP credential discovery against end hosts (Settings icon **–>** **Setup** **–>** **Discovery** **Settings** **–>** **Ranges** tab** –>** **Discovery** **Mode** menu).

- Use **Smart** **Subnet** **Ping** **Sweep** for complete end-host discovery. For information on Smart Subnet ping sweep, see *<span style="color: #0000ff">[Defining](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)*<span style="color: #0000ff">[Group](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)*<span style="color: #0000ff">[Data](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)*<span style="color: #0000ff">[Collection](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)*<span style="color: #0000ff">[Settings](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984067/Data+Collection+Techniques#DataCollectionTechniques-bookmark148)</span>*.

# > Macro (anchor)

> Macro (anchor)

Planning an Operations Center Deployment

A number of factors help decide what your Operations Center deployment will look like:

- *Define your goals for the network management system.*

Are you planning to manage only switched Ethernet networks? Manage all routed and switched networks? A mix of routing, switching, and security devices? Will you manage virtual routing and forwarding (VRF) networks?  
These factors bear upon the type of licensed feature set for the Operations Center, and how you will deploy it.

- *Estimate the size of the managed network.*

Operations Center feature licensing is defined by the number of licensed devices (including but not limited to routers, switches, firewalls and servers). Each managed device occupies a device license under NetMRI. The size of the managed network helps define the level of licensing you will need for the Operation Center deployment.  
Managed devices have a different licensing scheme from discovered devices. You allocate licenses based upon the infrastructure devices in your network that you want to manage; because the number of endpoint hosts may be far greater than the number of infrastructure devices, endpoints should be considered as part of the discovered devices category in most if not all cases. Discovered devices of this type should not be licensed unless considered necessary.  
Conversely, unlicensed infrastructure devices can lead to incomplete network analysis issues such as topology holes and large collections of undiscovered endpoints.

- *Determine how many Collector appliances you need, and how many device licenses should be provided on each Collector.*

Your decision on how many Collectors you need in your deployment is generally determined by the size and the topology of your network. For large deployments, contact Infoblox Support.  
Licensing levels are enforced on each Collector and cumulatively add to the total number of licenses for the Operations Center. On the Controller, you also install a specially generated license generated by Infoblox, directly based upon the features and device counts licensed for all Collectors in the full OC deployment.  
Knowing to a fairly close margin what device counts each of your Collectors will manage, while allowing room for growth, helps determine how the Controller will be licensed.

- *What is the rate of growth for the managed network?*

Plan for growth within the network when you define and set up the Operations Center deployment. A good rule of thumb is to plan for a minimum organic growth of 5% per year, but is entirely based upon the circumstances of each deployment and whatever future plans are in place for the managed network.

## > Macro (anchor)

> Macro (anchor)

Understanding Platform Limits for your Deployment

NetMRI provides a detailed System Health feature set that helps enforce key evaluation elements such as Platform Limits, Licensing Limits and Effective Limits for a deployment. For more information, see the section *<span style="color: #0000ff">[Understanding](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)</span>* *<span style="color: #0000ff">[Platform](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)*<span style="color: #0000ff">[Limits,](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)*<span style="color: #0000ff">[Licensing](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)*<span style="color: #0000ff">[Limits](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)*<span style="color: #0000ff">[and](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)*<span style="color: #0000ff">[Effective](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)*<span style="color: #0000ff">[Limits](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)</span>*.  
NetMRI Platform limits, Licensed limits, and Effective limits apply to all collector appliances and instances in an Operations Center. On the Operations Center, the Settings icon **–>** **Setup** **–>** **Tunnels** **and** **Collectors** page separately lists each collector's status and their associated device limits. For more information, see <span style="color: #0000ff">[*Checking NetMRI Collectors Operation*](#InstallingandDeployingtheNetMRIOperationsCenter-CheckingNetMRICollectorsOperation)</span>.

# > Macro (anchor)

> Macro (anchor)

Installing Operations Center Platforms

Take the following procedures to install and configure an Operations Center:

*<span style="color: #0000ff">[1st](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)*<span style="color: #0000ff">[Step:](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)*<span style="color: #0000ff">[Configuring](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)*<span style="color: #0000ff">[Basic](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)*<span style="color: #0000ff">[Settings](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)*<span style="color: #0000ff">[for](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)*<span style="color: #0000ff">[the](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)*<span style="color: #0000ff">[Operations](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)*<span style="color: #0000ff">[Center](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)*<span style="color: #0000ff">[Controller](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark900)</span>*

*<span style="color: #0000ff">[2nd](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[Step:](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[Installing](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[the](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[Operations](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[Center](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[License](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[on](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[the](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[Controller](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*

*<span style="color: #0000ff">[3rd](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[Step:](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[Running](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[Configure](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[Tunserver](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[on](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[the](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[Controller](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*

<span style="color: #0000ff">[*4th*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)<span style="color: #0000ff">[*Step:*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)<span style="color: #0000ff">[*Installation*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)<span style="color: #0000ff">[*for*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)<span style="color: #0000ff">[*Operations*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)<span style="color: #0000ff">[*Center*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)<span style="color: #0000ff">[*Collectors*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark903)</span>

*<span style="color: #0000ff">[5th](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)*<span style="color: #0000ff">[Step:](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)*<span style="color: #0000ff">[Installing](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)*<span style="color: #0000ff">[the](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)*<span style="color: #0000ff">[Operations](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)*<span style="color: #0000ff">[Center](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)*<span style="color: #0000ff">[Collector](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)*<span style="color: #0000ff">[License(s)](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*

*<span style="color: #0000ff">[6th](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)*<span style="color: #0000ff">[Step:](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)*<span style="color: #0000ff">[Registering](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)*<span style="color: #0000ff">[NetMRI](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)*<span style="color: #0000ff">[Collectors](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)</span>*

An Operations Center deployment consists of a controller appliance and one or more collector appliances. The Controller aggregates data and analyzes results from the collectors to provide a consolidated view of the enterprise network within one user interface, which is hosted by the controller.  
Communication between the Controller and its associated Collectors takes place over a set of Secure Sockets Layer Virtual Private Networks (SSL VPN) across their designated management network. You monitor Operations Center VPN tunnels and basic collector communication from the Settings icon **–>** **Setup** **–>** **Tunnels** **and** **Collectors** page. Each VPN tunnel between the Operations Center and the associated Collectors appear in the list.  
You begin installing an Operations Center platform by installing and configuring its Operations Center Controller, followed by installing and configuring its Collector appliances, whether physical or virtual.  
After physically installing the Collector appliances, or deploying the virtual machines to their respective hosts, activating their instances under the hypervisor and installing their Infoblox NetMRI licenses, you need to run a brief series of NetMRI Admin Shell (CLI) commands to bring up each instance.  
After finishing the basic Operations Center installation, you execute one of two different options:

- Configure the controller to use factory defaults;  
See <span style="color: #0000ff">[*Configuring*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark907)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark907)<span style="color: #0000ff">[*the*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark907)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark907)<span style="color: #0000ff">[*Operations*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark907)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark907)<span style="color: #0000ff">[*Center*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark907)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark907)<span style="color: #0000ff">[*Controller*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark907)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark907)<span style="color: #0000ff">[*with*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark907)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark907)<span style="color: #0000ff">[*Factory*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark907)</span>[* *](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark907)<span style="color: #0000ff">[*Defaults*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark907)</span>*;*

- Configure the controller to use data imported from an existing NetMRI appliance.   
See *<span style="color: #0000ff">[Importing](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[Data](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[From](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[a](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[Reference](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[NetMRI](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[Instance](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*.

# > Macro (anchor)

> Macro (anchor)

Installing the Operations Center Controller

You perform Operations Center Controller appliance installation before the Collector appliances are deployed for discovering their respective networks.  
Users connect to the NetMRI UI through the MGMT interface IP address on the Controller.

---

**Note:** Scan port configurations reside on each Collector appliance. The Operations Center Controller does no discovery or device management of its own; when you run **configure** **server** on the controller, you do not configure scan interfaces.

---

## > Macro (anchor)

> Macro (anchor)

1st Step: Configuring Basic Settings for the Operations Center Controller

You will need the following information to begin setting up the Controller:

- The Management IP address of the appliance (this IP will be assigned to the MGMT port of the appliance);
- A name for the global network to which NetMRI will initially connect and discover;
- The Default Gateway IP address for the management port;
- A designated controller name, if the default is not correct;
- The local domain name for the server network;
- Time zone and region information;
- DNS Server IP (and secondary DNS server IP if necessary);

There are two possibilities for basic IP configuration of the Controller:

- Static IP addressing using the **configure**** server** command;
- The appliance acts as a DHCP client, and the default values appear when you run the **configure ****server** command.

In this procedure, we assume use of a static IP address configuration for the Controller.

1. Use a terminal program to connect to the management IP address of the Controller appliance.
2. Log in using the default *admin/admin* username/password account.

---

**Note:** The values you enter in the **configure** **server** command are the default values that will appear in this series of steps. If your Operations Center is configured through DHCP, default values from that service appear here. Avoid overwriting DHCP-provided settings if this is the case.

---

3. At the Admin Shell prompt, enter **configure** **server** and press Enter.

`admin-na206.corp100.com> ``configure server`

4. Press **Y** to respond Yes to begin system setup.

Default values can be erased by pressing the spacebar and pressing Enter or by entering new values.

5. Enter the new Database Name and press Enter.

`Database Name is a descriptive name for this deployment. It is used in reports titles, headers, etc.`

`Recommended: Begin name with uppercase letter.`  
`Database Name []: ``Corp100_west`

6. For the first-time installation, you can choose to generate a new HTTPS certificate.

`Do you want to generate a new HTTPS Certificate? (y/n) [n]: ``y`

7. Enter the local domain name in which the controller resides. This value is used for truncating device names in NetMRI data sets throughout the system.

`Domain Name 1 (e.g., example.com) []: ``corp100.com`  
`Domain Name 2 (optional) []:`

8. Enter the time server IP address if one is available or is necessary:

`Time Server [us.pool.ntp.org]:`

9. Enter the time zone region by typing in the suggested numeric value from the list:

`Time Zone Regions`  
` Choose your local region.`

|  |  |  |  |  |  |  |  |
| --- | --- | --- | --- | --- | --- | --- | --- |
| `0.` | `Africa` | `1.` | `Antarctica` | `2.` | `Arctic` | `3.` | `Asia` |
| `4.` | `Atlantic` | `5.` | `Australia` | `6.` | `Brazil` | `7.` | `Canada` |
| `8.` | `CET` | `9.` | `Chile` | `10.` | `EET` | `11.` | `GMT` |
| `12.` | `GMT-1` | `13.` | `GMT+1` | `14.` | `GMT-2` | `15.` | `GMT+2` |
| `16.` | `GMT-3` | `17.` | `GMT+3` | `18.` | `GMT-4` | `19.` | `GMT+4` |
| `20.` | `GMT-5` | `21.` | `GMT+5` | `22.` | `GMT-6` | `23.` | `GMT+6` |
| `24.` | `GMT-7` | `25.` | `GMT+7` | `26.` | `GMT-8` | `27.` | `GMT+8` |
| `28.` | `GMT-9` | `29.` | `GMT+9` | `30.` | `GMT-10` | `31.` | `GMT+10` |
| `32.` | `GMT-11` | `33.` | `GMT+11` | `34.` | `GMT-12` | `35.` | `GMT+12` |
| `36.` | `Europe` | `37.` | `Hongkong` | `38.` | `Iceland` | `39.` | `Indian` |
| `40.` | `Israel` | `41.` | `Mexico` | `42.` | `NZ` | `43.` | `NZ-CHAT` |
| `44.` | `Pacific` | `45.` | `US` | `46.` | `UTC` | `47.` | `WET` |

`Enter choice (0-47) [0]: 45`

10. Enter the time zone location by typing in the suggested numeric value from the list:

`Choose a location within your time zone.`

|  |  |  |  |  |  |  |  |
| --- | --- | --- | --- | --- | --- | --- | --- |
| `0.` | `Alaska` | `1.` | `Aleutian` | `2.` | `Arizona` | `3.` | `Central` |
| `4.` | `East-Indiana` | `5.` | `Eastern` | `6.` | `Hawaii` | `7.` | `Indiana-Starke` |
| `8.` | `Michigan` | `9.` | `Mountain` | `10.` | `Pacific` | `11.` | `Samoa` |

`Enter choice (0-11) [0]: ``10`

11.Follow the steps for configuring the management port IP settings:

`+++ Configuring Management Port Settings`  
`You must configure an IPv4 or IPv6 address/mask on the management port.`  
`NetMRI can perform analysis from the management port or a separate scan port.`

`IP Address (optional) []: ``10.120.25.212`  
`Subnet Mask (optional) []: ``255.255.255.0`  
`IPv6 Address (optional):`  
`IPv6 Prefix (optional):`

`You must provide either an IPv4 gateway, an IPv6 gateway, or both.`

`IPv4 Default Gateway (optional) []: ``10.120.25.1`  
`IPv6 Default Gateway (optional) []:`

12.Enter n for No and press Enter to skip the step for configuring the SCAN port on the Controller appliance:

`Do you want to configure the Scan Port? (y/n) [n]: <enter>`  
You will not use the SCAN ports LAN1 and LAN2 on the Controller appliance in an OC deployment.

13.Enter the address(es) of the primary and secondary DNS server, if required:

`DNS Server 1 (IP) []: ``172.23.16.21`  
`DNS Server 2 (optional) []:`

14.The setup utility lists the configuration settings and queries whether you wish to edit them.

`Edit these settings? (y/n) [n]:`

15.Finally, the setup utility requests that you commit your settings. Press Enter to accept the **Y** (yes) default.

`Configure the system with these settings? (y/n) [y]:`

  
`Configuring system ...`  
`+++ Validating Interfaces ...`  
`+++++ eth0 ... OK`  
`+++++ eth1 ... OK`  
`The controller appliance restarts.`

16.Verify your settings by entering the following:

`admin-na206.corp100.com> ``show settings`  
This command lists the complete config settings for the Operations Center.

For the controller appliance, continue to the next topic, *<span style="color: #0000ff">[2nd](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[Step:](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[Installing](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[the](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[Operations](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[Center](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[License](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[on](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)*<span style="color: #0000ff">[the](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>* *<span style="color: #0000ff">[Controller](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark901)</span>*.

## > Macro (anchor)

> Macro (anchor)

2nd Step: Installing the Operations Center License on the Controller

You must install the cumulative feature license provided to you by Infoblox Sales & Support for the Controller to fully operate with all Collectors in the deployment. This license must contain the aggregate count of device licenses and feature entitlements that are provided for all Collectors expected to work with the OC Controller system.  
When you receive the Controller appliance and physically install it, it does not automatically contain the licensed features and entitlements present on the Collectors, nor can those entitlements be transferred to the Controller. When you first set up the appliances that you are designating as Collectors in an OC deployment, they are simply operating as standalone NetMRI appliances. Each are separately licensed. The Controller has its own cumulative license file. You install that license in this step, followed by step 2a, re-running **configure** **server** on the Controller appliance.

To install the Operations Center license for a NetMRI physical appliance, generate a license on your own using the **license generate** administrative shell command. For more information, see [license generate command](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984014/Administrative+Shell#AdministrativeShell-LicenseGenerateCommand).

To install the Operations Center license for a NetMRI virtual appliance, do the following:

1. Obtain the Operations Center license through the Infoblox Support Portal at [http://support.infoblox.com](http://support.infoblox.com/).
2. Upload the license file provided through the Infoblox Support Portal into the admin account's **/Backup** directory using WinSCP or a similar program.
3. Log into the admin shell, enter the `license <NameOfLicenseFile>` command, and press Enter.  
admin-na206.corp100.com> **license <license_file_name.gpg>**  
The server restarts without rebooting the appliance. The server resumes operation after several minutes of processing.

### Step 2a: Re-Run Configure Server

After you install the license for your Controller, you must run the **configure** **server** command a second time.

1. After logging in to the Controller appliance, re-run the **configure** **server** command:  
`admin-na206.corp100.com> ``configure server`
2. Press **Y** to respond Yes to continue system setup. You step through the settings you defined in your first run of the **configure** **server** command by pressing Enter at each prompt. (You do not need to change any settings unless changes are required for administrative reasons.) When you come to the end of the **configure** **server** command sequence, enter **N** to commit the previously defined settings to the system.
  `Configure the system with these settings? (y/n) [y]: ``n`
  `Configuring system ...`
  `+++ Validating Interfaces ...`
  `+++++ eth0 ... OK`
  `+++++ eth1 ... OK`
  The controller appliance restarts.
3. Continue to the next topic, *<span style="color: #0000ff">[3rd](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[Step:](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[Running](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[Configure](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[Tunserver](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[on](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[the](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[Controller](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*.

## > Macro (anchor)

> Macro (anchor)

3rd Step: Running Configure Tunserver on the Controller

The **configure** **tunserver** command governs the core security settings for the Controller appliance, including certificate usage and the VPN tunnel server settings between the Controller and all collectors.  
The command also offers the option to define a reference NetMRI appliance to use for importing the library of scripts, custom reports, custom jobs, policies and user account data from an existing appliance. For more information, see the following section, *<span style="color: #0000ff">[Importing](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[Data](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[From](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[a](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[Reference](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[NetMRI](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[Instance](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*.

1. Use a terminal program to connect to the management IP address of the Controller appliance.
2. Log in using the default *admin/admin* username/password account.
3. Execute the following Admin Shell CLI commands on a newly installed or reset Operations Center appliance:

`NetworkAutomation-VM-8DD4-66925>`` configure tunserver`

`+++ Configuring CA Settings`

`CA key expiry in days [5475]:`

`CA key size in bits [2048]:`

`+++ Configuring Server Settings`

`Server key expiry in days [5475]:`

`Server key size in bits [1024]:`

`Server Public Name or IP address: ``10.120.32.167`

`Protocol (tcp, udp, udp6) [tcp]:`

`Tunnel network base [5.0.0.0]:`

`Block cipher:`

`0. None (RSA auth)`

`1. Blowfish-CBC`

`2. AES-128-CBC`

`3. Triple DES`

`4. AES-256-CBC`

`Enter Choice [2]:`

Use compression [y]:

You can optionally designate a NetMRI client system as a "reference" system

that will be used as a source of common settings.

Enter reference system serial number or RETURN to skip:

Use these settings? (y/n) [n]: **y**

The system will commit the settings and restart the software without rebooting the system.

To check operation of VPN tunnel connections with Collector appliances, go to Settings icon **–> Setup –> Tunnels & Collectors** on the Controller.

## > Macro (anchor)

> Macro (anchor)

4th Step: Installation for Operations Center Collectors

Scan port configurations reside on each Collector appliance. The Operations Center Controller does no discovery or device management of its own; when you run **configure** **server** on the controller, you do not configure the LAN1 port. The following procedure applies only to Collector appliances.  
You will need the following information to begin setting up the Collector:

- The Management IP address of the appliance (this IP will be assigned to the MGMT port of the appliance);
- The customer name for the network to which the appliance will initially connect and discover;
- The Default Gateway for the management port;
- The local domain name for the server network;
- Time zone and region information;
- DNS Server IP (and secondary DNS server IP if necessary);

There are two possibilities for basic IP configuration of each Collector:

- Static IP addressing using the **configure**** server** command;
- Appliance uses DHCP, and the default values appear when you run the **configure**** server** command.   
In this procedure, we assume use of a static IP address on the management network for each Collector.

1. Use a terminal program to connect to the management IP address of the Collector appliance.
2. Log in using the default *admin/admin* username/password account.
3. At the Admin Shell command prompt, enter **configure** **server** and press Enter.
4. Complete the following:

---

**Note:** If your Operations Center Collectors are configured through DHCP, default values from that service will appear here. Do not override DHCP settings while using the **configure** **server** command. In this procedure, we assume use of a static IP address on the management network for each Collector.

---

5. At the Admin Shell prompt, enter **configure server** and press Enter.

6. Press **Y** to respond Yes to begin system setup:

`Do you want to start system setup now? (y/n) [n]: y`


`Default values, when available, are given within [].`

`You may clear defaults by typing a SPACE and pressing Enter.`

`+++ Configuring Network Identification Settings`

7. Enter the new Database Name and press Enter.

`Database Name is a descriptive name for this deployment. It is used in reports titles, headers, etc.`  
`Recommended: Begin name with uppercase letter.`

  
`Database Name []:`` Corp100_west`

8. Enter the new Server Name and press Enter.

`The Server Name identifies this system in SNMP and HTTPS server certificates.`  
`The installed HTTPS certificate contains the following subject:`

`subject= /CN=NetworkAutomation-2210201208100028/O=NetMRI`

  
`Server Name []:`` corp100_187`

9. For the first-time installation, you can choose to generate a new HTTPS certificate.  
`Do you want to generate a new HTTPS Certificate? (y/n) [n]: ``y`  
10. Enter the local domain name in which the appliance resides. This value is used for truncating device names in NetMRI data sets throughout the system.  
`Domain Name 1 (e.g., example.com) []: ``corp100.com`  
`Domain Name 2 (optional) []:`  
11. Enter the time server IP address if one is available:  
`Time Server [us.pool.ntp.org]:`  
12 .Enter the time zone region by typing in the suggested numeric value from the list:  
Time Zone Regions  
Choose your local region.

`Time Zone Regions`  
` Choose your local region.`

|  |  |  |  |  |  |  |  |
| --- | --- | --- | --- | --- | --- | --- | --- |
| `0.` | `Africa` | `1.` | `Antarctica` | `2.` | `Arctic` | `3.` | `Asia` |
| `4.` | `Atlantic` | `5.` | `Australia` | `6.` | `Brazil` | `7.` | `Canada` |
| `8.` | `CET` | `9.` | `Chile` | `10.` | `EET` | `11.` | `GMT` |
| `12.` | `GMT-1` | `13.` | `GMT+1` | `14.` | `GMT-2` | `15.` | `GMT+2` |
| `16.` | `GMT-3` | `17.` | `GMT+3` | `18.` | `GMT-4` | `19.` | `GMT+4` |
| `20.` | `GMT-5` | `21.` | `GMT+5` | `22.` | `GMT-6` | `23.` | `GMT+6` |
| `24.` | `GMT-7` | `25.` | `GMT+7` | `26.` | `GMT-8` | `27.` | `GMT+8` |
| `28.` | `GMT-9` | `29.` | `GMT+9` | `30.` | `GMT-10` | `31.` | `GMT+10` |
| `32.` | `GMT-11` | `33.` | `GMT+11` | `34.` | `GMT-12` | `35.` | `GMT+12` |
| `36.` | `Europe` | `37.` | `Hongkong` | `38.` | `Iceland` | `39.` | `Indian` |
| `40.` | `Israel` | `41.` | `Mexico` | `42.` | `NZ` | `43.` | `NZ-CHAT` |
| `44.` | `Pacific` | `45.` | `US` | `46.` | `UTC` | `47.` | `WET` |

`Enter choice (0-47) [0]: 45`

13. Enter the time zone location by typing in the suggested numeric value from the list:

`Choose a location within your time zone.`

|  |  |  |  |  |  |  |  |
| --- | --- | --- | --- | --- | --- | --- | --- |
| `0.` | `Alaska` | `1.` | `Aleutian` | `2.` | `Arizona` | `3.` | `Central` |
| `4.` | `East-Indiana` | `5.` | `Eastern` | `6.` | `Hawaii` | `7.` | `Indiana-Starke` |
| `8.` | `Michigan` | `9.` | `Mountain` | `10.` | `Pacific` | `11.` | `Samoa` |

`Enter choice (0-11) [0]: 10`

You continue by configuring the management port settings. You define the IPv4 and IPv6 addresses and subnet masks the default gateway IP address for the management port:

`You must configure an IPv4 or IPv6 address/mask on the management port.`

`NetMRI can perform analysis from the management port or a separate scan port.`

`IPv4 Address (optional) []: 10.120.32.181`

`IPv4 Subnet Mask (optional) []: ``255.255.255.0`

`IPv6 Address (optional):`

`IPv6 Prefix (optional):`

`IPv4 Default Gateway (optional) []: ``10.120.32.1`

`IPv6 Default Gateway (optional) []:`

---

**Note**: When registering a Collector to the OC, make sure that they both are in the same time zone. Use the `configure server` command to set the Collector time zone to match the OC (US/Eastern). Changing the time zone requires a system reboot.

---

14. Press **Y** (yes) to perform the step for configuring the LAN1 port on the collector appliance:

`Do you want to configure the Scan Port? (y/n) [n]: ``y`

`You must configure an IPv4 or IPv6 address/mask on the scan port.`

`IP Address (optional) []: 10.0.60.181`

`Subnet Mask (optional) [] ``255.255.255.0 :`

`IPv6 Address (optional):`

`IPv6 Prefix (optional):`

`You must provide either an IPv4 gateway, an IPv6 gateway, or both.`

`IPv4 Default Gateway (optional) [] ``10.0.60.1 :`

`IPv6 Default Gateway (optional) []:`

15. Enter the address(es) of the primary and secondary DNS server, if required:

`DNS Servers are used to map hostnames to IP addresses.`

`You may enter up to 2 name servers below.`

`DNS Server 1 (IP) []: ``172.23.16.21`

`DNS Server 2 (optional) []:`

16. The setup utility lists the configuration settings and queries whether you wish to edit them.

`Edit these settings? (y/n) [n]:`

17. The setup utility requests that you commit your settings. Press Enter to accept the **Y** (yes) default.

`Configure the system with these settings? (y/n) [y]:`


`Configuring system ...`

`+++ Validating Interfaces ...`

`+++++ eth0 ... OK`

`+++++ eth1 ... OK`

The Collector appliance restarts.

You continue by installing the license for each Collector appliance. Continue to the next topic, <span style="color: #0000ff">[*5th Step: Installing the Operations Center Collector License(s)*](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark904)</span>*<span style="color: #0000ff">.</span>*

## > Macro (anchor)

> Macro (anchor)

5th Step: Installing the Operations Center Collector License(s)

You will need the following information to correctly license all Collectors in the deployment:

- Each Collector appliance's required feature licenses (Full NetMRI, or Automation Change Management (ACM));
- The number of licensed devices that each Collector is expected to manage.

In an OC deployment, each NetMRI Collector license is provided from the Infoblox Support Portal. Once you bring the appliances up, they are simply operating as standalone NetMRI appliances.

1. Obtain an Operations Center license from Infoblox.
2. Upload the license file provided by Infoblox into the admin account's /Backup directory using WinSCP or a similar program.
3. Log into the admin shell and enter the` license <NameOfLicenseFile>` command, and press Enter.   
The NetMRI service restarts without rebooting the appliance. NetMRI resumes operation after several minutes of processing.
4. Continue to the next section, *<span style="color: #0000ff">[6th](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)*<span style="color: #0000ff">[Step:](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)*<span style="color: #0000ff">[Registering](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)*<span style="color: #0000ff">[NetMRI](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)*<span style="color: #0000ff">[Collectors](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark905)</span>*.

## > Macro (anchor)

> Macro (anchor)

6th Step: Registering NetMRI Collectors

To complete the basic Operations Center deployment, you run the **register** command in the Admin Shell on each Collector to register them with the newly configured Operations Center.

---

**Note:** Managed device licenses are enforced on each of the collectors for the Operations Center, not on the central Operations Center node. The Operations Center node must contain a license encompassing the scope of all licenses between all Collectors.

---

1. Use a terminal program to connect to the management IP address of each Collector appliance.
2. Log in using the default *admin/admin* username/password account.
3. Execute the following Admin Shell CLI commands on a newly installed or reset Operations Center appliance:

`admin-na206.corp100.com> ``register`  
`NOTICE: The inactivity timeout is being disabled temporarily while this command is run.`

  
`+++ Configuring Tunnel Registration Settings`

`Registration Server/IP [e.g., example.com]: ``10.1.21.2`  
`Registration protocol (http|https) [https]:`  
`Registration username: ``admin`  
`Registration password:#$^%#*#$`

  
`Register this system? (y/n) [y]:``y`

4. Press Y to establish the secure communication link between the Collector and the Operations Center appliance.

You can migrate from a standalone NetMRI appliance to an Operations Center environment. This procedure is described in the following section, *<span style="color: #0000ff">[Importing](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[Data](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[From](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[a](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[Reference](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[NetMRI](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)*<span style="color: #0000ff">[Instance](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark906)</span>* section.

## > Macro (anchor)

> Macro (anchor)

Importing Data From a Reference NetMRI Instance

The appliance designated as a Controller can import the library of scripts, custom reports, custom jobs, policies and user account data from an existing NetMRI appliance. The NetMRI appliance from which you are importing does not become the Controller itself.

1. Choose the NetMRI instance as a reference system from which data will be copied.

*Only* *information* *from* *the* *reference* *NetMRI* *can* *be* *imported* *into* *the* *Operations* *Center.* When adding multiple NetMRI instances to an Operations Center environment, the scripts, policies and settings may differ between NetMRI instances. Therefore, any of the deltas you want imported into the Operations Center must either be manually added to the reference NetMRI, or imported into the Operations Center after the reference NetMRI is restored on the Operations Center.

2. Configure the Controller:

> Macro (legacy-content)

---

**Tip**: In each prompt, defaults are shown in square brackets [ ]. To accept the default, simply press ENTER.

---

d. When prompted: `Use these settings?`, enter **y**.

e. When prompted to restart the Controller, enter **y**.

The complete package of scripts, policies and user data is downloaded by the Operations Center. You install the data in a following step.

3. Register the reference system with the Controller:

> Macro (legacy-content)

4. Define restore settings on the Controller: (This installs the uploaded reference data.)

> Macro (legacy-content)

5. Re-register the reference unit with the Controller.

> Macro (legacy-content)

---

**Note:** As part of the registration process, the admin password on each collector synchronizes with the password on the Operations Center Controller. After registration completes, the admin password for the collector may be different than the password you initially used to log in to the admin shell on that instance.

---


---

**Note:** After registration, the NetMRI GUI is not available on the reference NetMRI unit. All access to the unit takes place through the Controller.

---

## > Macro (anchor)

> Macro (anchor)

Configuring the Operations Center Controller with Factory Defaults

This procedure describes the straightforward process of setting up an Operations Center Controller with factory defaults. No configuration data or network and device information is imported from any NetMRI reference system.

1. Log in to the NetMRI admin shell.
2. Enter **configure** **tunserver**.
3. When prompted to `Enter the reference system serial number or RETURN to skip`, press ENTER.
4. Proceed to build out the system, by following the procedures in the section *<span style="color: #0000ff">[Installing](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark899)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark899)*<span style="color: #0000ff">[the](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark899)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark899)*<span style="color: #0000ff">[Operations](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark899)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark899)*<span style="color: #0000ff">[Center](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark899)</span>* *<span style="color: #0000ff">[Controller](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark899)</span>*.

## > Macro (anchor)

> Macro (anchor)

Installing an Operations Center License onto an Existing NetMRI Appliance

Installing an Operations Center license is a process that should only be done on appliances that are qualified to operate as such. Otherwise, the process is straightforward.

1. Convert the NetMRI appliance to an Operations Center Controller:
  1. Obtain an Operations Center license from Infoblox.
  2. Upload the license into the admin account's /Backup directory using WinSCP or a similar program.
  3. Log into the admin shell and enter the **license ****<NameOfLicenseFile>** command.
2. Log in to the admin shell and enter **configure**** tunserver**. Answer the prompts to set up the basic tunnel server settings, as described in the section *<span style="color: #0000ff">[3rd](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[Step:](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[Running](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[Configure](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[Tunserver](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[on](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[the](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*[ ](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)*<span style="color: #0000ff">[Controller](#InstallingandDeployingtheNetMRIOperationsCenter-bookmark902)</span>*.

# > Macro (anchor)

> Macro (anchor)

Configuring Network Interfaces for Operations Center

NetMRI requires a connection to each network you wish to directly discover, manage or control. Scan Interfaces are the ports on NetMRI appliances and virtual appliances that perform this function. Physical scan interfaces are actual Ethernet ports on the appliance.  
You can configure *virtual* *scan* *interfaces* on Collector appliances, that use 802.1Q VLAN tagging between NetMRI and its connecting device, to exchange traffic for multiple networks across a single physical interface. To use virtual scan interfaces, you connect one of NetMRI's physical scan interfaces to a device interface configured to route the desired networks with 802.1Q VLAN tags.  
You define physical scan interfaces and virtual scan interfaces on Operations Center Collectors. All scan interfaces of either type must be bound to a *network* *view* to enable network management across each interface.  
Each network views also requires discovery settings to discover the network.

## > Macro (anchor)

> Macro (anchor)

Network Views and Scan Interfaces

---

**Note:** You associate all network discovery settings, including discovery ranges, static IPs and seed routers, with each network view. For information about configuring your network views, see *<span style="color: #0000ff">[Configuring](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark99)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark99)*<span style="color: #0000ff">[Network](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark99)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark99)*<span style="color: #0000ff">[Views](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark99)</span>* and *<span style="color: #0000ff">[Configuring](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark112)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark112)*<span style="color: #0000ff">[Network](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark112)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark112)*<span style="color: #0000ff">[Discovery](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark112)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark112)*<span style="color: #0000ff">[Settings](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984119/Introduction#Introduction-bookmark112)</span>*.

---

You use network views in combination with scan interfaces to separate and manage networks. If you plan to manage a number of networks of any kind (routed networks, virtual routing and forwarding (VRF) networks, and so on), network views, each tied to a scan interface, give you the flexibility to do so.  
Network views provide the useful concept of *isolation*. Using network views, NetMRI enables you to manage networks that may have overlapping IP prefixes or address ranges, preventing addressing conflicts between separately managed networks. You manage every network in complete isolation from other networks.  
In previous Operations Center software versions, a model termed the multi-tenancy multi-collector deployment enables either of the following:

- Multiple collectors on a single network (for managing an exceptionally large network).

For an OC deployment of this type, you choose the network view-collector entry from the **Network****View** list. You will see multiple entries in the pages under Settings icon **–>****Setup****–>****Discovery****Settings** for the **Network****View** list. The entire network is assigned to a single network view; however, each network view entry is identified through the association of each Collector. This allows you to edit discovery settings for each Collector in the same network view. Examples:

`corp100_west (NM35) `

`copr100_west (NM36)`

Here each Collector, NM35 and NM36, is associated to the same network view, but discovery settings can be  
edited separately.

- Multiple networks, each assigned to one collector.

This is the Multi-Network model. Each Collector is assigned to its own separate network view, which is bound to the scan interface on each Collector. Any Collector can also manage through multiple network views, each of which is considered a separate routing domain

Through virtual scan interfaces and multiple scan ports, combined with network views, you may have multiple scan interfaces per collector, and therefore multiple networks per collector. This extends the multi-tenancy multi-collector model to allow each collector in the Operations Center to flexibly discover, catalogue and manage multiple networks.

---

**Note:** If you have multiple networks, particularly with overlapping IP address ranges, you can define virtual scan interfaces to tie NetMRI to each network without affecting the operation of those overlapping address spaces.

---

## > Macro (anchor)

> Macro (anchor)

Configuring Physical Scan Interfaces on Collectors

Collector physical scan interface configuration varies depending on your Collector's physical configuration, and even whether the appliance is a VM.  
To configure a physical scan interface, do the following:

1. Go to Settings icon **–> ****Setup**** –> ****Scan**** Interfaces**.  
The Scan Interfaces Settings page appears, listing all device interfaces that may be used by the appliance. Depending on the hardware and system type, you will see one or more interfaces named MGMT and/or LAN*n* (where *n* is the physical port number). In an Operations Center, the **Collector** **Name** is shown alongside the interfaces.
2. Hover over the Action icon for any of the physical ports and select **Edit** from the menu.
3. Choose from the **Network** **View** configuration section:
  1. **Select** **Existing**: Choose a network view from the list of existing ones that are defined on the system;
    - Select the view from the dropdown list;
    - Selecting **Unassigned** as the Network View leaves the interface in a disabled state.

–or–

b. **Create** **New**: Creates a new network view.

> Macro (legacy-content)

4. Enter the **IPv4**** Address**, **IPv4**** Subnet**** Mask** and the **IPv4**** Default**** Gateway**; or, enter the **IPv6**** Address**, **IPv6**** Subnet ****Mask** and the **IPv6 ****Default**** Gateway** values if the connection supports IPv6 in addition to, or instead of, IPv4.

5. Click **Save** to save the new physical scan interface configuration. On physical ports, you may **Edit** or **Add ****Virtual**** Scan**** Interface**s.

---

**Note:** Though the MGMT port provides allows for the same scanning discovery and device control capabilities as other appliance physical port types, Infoblox recommends limiting managing enterprise networks through the MGMT port, using it only for management access to the appliance's web, cli and tunnel interfaces, so those functions cannot be compromised by end-user traffic.

---

## > Macro (anchor)

> Macro (anchor)

Configuring Virtual Scan Interfaces on Collectors

To define virtual scan interfaces, do the following:

1. Go to Settings icon **–>** **Setup** **–>** **Scan** **Interfaces**.   
The **Scan** **Interfaces** page appears, listing all device interfaces that may be used by the appliance. Depending on the hardware and system type, you will see one or more interfaces named MGMT and/or LAN*n* (where *n* is the physical port number). If any virtual scan interfaces are defined, they will have names like LAN1.211 (NM35) (the '211' is the 802.1Q tag defined for the virtual scan interface, and the 'NM35' is the Collector ID).   
The **Scan** **Interfaces** page lists all physical scan interfaces and virtual interfaces by each collector appliance.
2. Hover over the Action icon for any of the physical ports and select **Add** **Virtual** **Scan** **Interface** from the menu.
3. Choose from the **Network** **View** configuration section:
  1. **Select** **Existing**: Choose a network view from the list of existing network views that are defined in NetMRI;
    - Select the view from the dropdown list;
    - Selecting **Unassigned** as the Network View leaves the interface in a disabled state. The **Network** **View** field remains blank in the Scan Interfaces table.

–or–

b. **Create New**: Creates a new network view.

> Macro (legacy-content)

4. In the **Tag** field, enter the 802.1Q tag value defined on the facing device that transits the trunk port or router port. You will need to know the tag value on the device.

5. Enter the **IPv4**** Address**, **IPv4**** Subnet**** Mask** and the **IPv4**** Default**** Gateway**; or, enter the **IPv6**** Address**, **IPv6****Subnet**** Mask** and the **IPv6 ****Default**** Gateway** values if the connection supports IPv6 in addition to, or instead of, IPv4.

6. Click **Save** to save the new virtual scan interface configuration. You may also **Edit** or **Delete** virtual scan interfaces.

Remember the following points about scan interface configuration:

- You can assign a network view to a physical port on your appliance, such as LAN1. Doing so does not prevent the same port from supporting virtual scan interfaces, each of which supports their own network view;
- You can define virtual scan interfaces and assign network views to them, but choose not to apply a network view to the physical port hosting those virtual scan interfaces (LAN1, for example);
- You can create a virtual scan interface with a tagging value, but not immediately assign it to a network view. The virtual scan interface is effectively disabled and you can assign its network view at a later time;
- On each Collector appliance, each network view can be associated with a single scan interface. Multiple Collectors can each access the same network view, each using separate discovery settings.

# > Macro (anchor)

> Macro (anchor)

Operations Center Disaster Recovery Procedure

---

**Note:** Ensure that the standby Operations Center appliance and/or all standby collectors use the same NetMRI software release as those in production before continuing with this procedure.

---

This topic describes how to perform a disaster recovery from a Primary Operations Center to a Standby Operations Center. When you perform a disaster recovery, you first restore the database archive on the Standby Operations Center, and then migrate all collectors from the Primary Operations Center to the Standby Operations Center

---

**Note:** To fully configure the Standby Operations Center, you will need a second product license for the disaster recovery system with the same licensing entitlements as the Primary Operations Center license. Contact your Infoblox sales representative for more information.

---

Complete the following to perform a disaster recovery:

1. Log in to the Standby Operations Center command line via SSH using the admin/admin system credentials.
2. Execute the following Admin Shell CLI commands on a newly installed or reset Standby Operations Center instance:

- Define the management port IP configuration for the Standby Operations Center:  
`admin-na206.corp100.com> ``configure server`
- Install the license for the Standby Operations Center:
  - For a physical appliance, generate a license by running the **license generate** command. For more information, see <span style="color: #0000ff">[*license generate command*](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984014/Administrative+Shell#AdministrativeShell-LicenseGenerateCommand)</span>.
  - For a virtual appliance, run admin-na206.corp100.com> **license <license filename>.gpg**.

- Define server settings for the Standby Operations Center:  
`admin-na206.corp100.com> ``configure server`

Make a note of your settings for Step 6 of this Procedure.

---

**Note:** The **configure** **server** command also generates a new self-signed certificate for the Standby Operations Center. In cases where a CA-signed certificate is used in the original Operations Center, the HTTPS certificates need to be configured using the procedures described in the topic <span style="color: #0000ff">[*NetMRI Security Settings*](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27984101)</span> in the Admin Guide and in the online Help.

---

3. Verify your settings by entering the following commands:

`admin-na206.corp100.com> ``show settings`  
List the complete config settings for the Standby Operations Center.  
`admin-na206.corp100.com> ``show license`  
Show the installed license for the Standby Operations Center.

4. Via SCP, manually transfer the Primary Operations Center database archive to the Standby Operations Center.

---

**Note:** You can also configure the database backup for the Primary as an automated transfer, using the **Settings**** –>** **Database** **Settings** **–>** **Scheduled** **Archive** screen on the Primary Operations Center to archive the OC database to the system designated as the Standby. The backup directory in this case should be set as "Backup"; for more information, see *<span style="color: #0000ff">[Database](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983912/NetMRI+Database+Management#NetMRIDatabaseManagement-bookmark816)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983912/NetMRI+Database+Management#NetMRIDatabaseManagement-bookmark816)*<span style="color: #0000ff">[Archiving](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983912/NetMRI+Database+Management#NetMRIDatabaseManagement-bookmark816)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983912/NetMRI+Database+Management#NetMRIDatabaseManagement-bookmark816)*<span style="color: #0000ff">[Functions](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983912/NetMRI+Database+Management#NetMRIDatabaseManagement-bookmark816)</span>* in the Admin Guide and in the online Help.

---


---

**Note:** When using the automated database backup, you must first log in to the Standby Operations Center through your web browser, and set the admin password to a value different from the "admin" factory default.  
In this case, after the Standby OC system is activated as the Primary, you must also go to the **Settings** **–>** **Database** **Settings** **–>** **Scheduled** **Archive** tab and define another remote system to back up the new OC's database archive.

---

If you schedule the transfer to occur within six hours of the start of weekly maintenance, no new archive will be created. Instead, the archive generated by weekly maintenance will be used. For large deployments with a lot of data, configuring backups to occur more frequently than the weekly interval may affect overall system performance.

5. Using the Admin Shell on the Standby Operations Center, restore the database archive on the Standby Operations Center. Restore time depends upon the size of the database, and may take several hours for a large system.

`admin-na206.corp100.com> ``restore ExampleNet_4050201203200004-20130221-641`

---

**Note:** The admin credentials (that default to admin/admin) are changed on the Standby Operations Center following the database restore operation. The Standby Operations Center will use the admin credentials that previously applied on the Primary Operations Center.

---

6. When the database restore task finishes on the Standby Operations Center, run **configure** **server** a second time to regenerate the Standby Operations Center's self-signed certificate for HTTPS access. Retain your settings previously defined in Step 2 of this Procedure.

7. In the Admin Shell on the Standby Operations Center, configure the VPN tunnel server on the Standby Operations Center using the same VPN subnet and other settings as on the Primary. When asked for the **Server ****Public**** Name**** or ****IP**** address**, be sure to enter the correct value for the Standby Operations Center. Do not configure a reference collector. The following listing is a sample capture for an entire session:

`admin-na206.corp100.com>`` configure tunserver`  
`+++ Configuring CA Settings`

`CA key expiry in days [5475]:`  
`CA key size in bits [1024]:`

`+++ Configuring Server Settings`

`Server key expiry in days [5475]:`  
`Server key size in bits [1024]:`

`Server Public Name or IP address: 172.23.27.170 <new IP address for Standby>`

`Protocol (tcp, udp, udp6) [tcp]:`  
`Tunnel network base [5.0.0.0]:`  
`Block cipher:`

`0. None (RSA auth)`

`1. Blowfish-CBC`

`2. AES-128-CBC`

`3. Triple DES`

`4. AES-256-CBC`

`Enter Choice [2]:`

`Use compression [y]:`

`You can optionally designate a NetMRI client system as a "reference" system that will be used as a source of common settings.`

`Enter reference system serial number or RETURN to skip: ``<press Enter here>`

`Use these settings? (y/n) [n]: y`

`+++ Initializing CA (may take a minute) ...`

`+++ Creating Server Params and Keypair ...`

`Generating DH parameters, 1024 bit long safe prime, generator 2`

`This is going to take a long time`

`....++*++*++*`

`+++ Creating Server Config ...`

`Successfully configured Tunnel CA and Server`

`The server needs to be restarted for these changes to take effect.`

`Do you wish to restart the server now? (y/n) [y]: y`

`+++ Restarting Server ... OK`

8. Check the Standby Operation Center’s VPN tunnel server settings, which are used for communications between the Operations Center and its collectors, before proceeding:

`example-oc> ``show tunserver`

`CA configured: Yes`

`Server configured: Yes`

`ServerPublicName: 172.23.27.170`

`Proto: tcp`

`Port: 443`

`KeySize: 1024`

`Network: 5.0.0.0`

`Cipher: AES-128-CBC`

`Compression: Yes`

`Service running: Yes`

`Reference NetMRI SN: N/A`

`Reference NetMRI Import: Skipped`


`Client Sessions:`

`UnitSerialNo: 1200201202100020`

`UnitName: oc-170-coll-1`

`UnitIPAddress: 5.0.0.15`

`Network: ExampleNet`

`UnitID: 1`

`Status: Offline: Last seen 2013-02-21 03:01:01`

`...`

9. Using a Web browser, log in to the Standby Operations Center. Note that the admin password for the Standby Operations Center system will now be set to the password of the Primary Operations Center.

10.In **Settings –> Setup –> Collection and Groups**, re-enable all data collectors needed for the configuration.

---

**Note:** You must re-enable **SNMP** **collection** on this page, as it is automatically disabled on a restore.

---

11. In **Settings** **–>** **Setup** **–>** **Tunnels** **and** **Collectors**, verify that all collectors are listed.

12. Register the collectors to the Standby Operations Center by executing the following commands on each of the collectors. You use these commands to specify the Standby Operations Center IP address and new admin credentials:

`admin-collector111.corp100.com> ``reset tunclient`  
` admin-collector111.corp100.com> ``register`

13. Verify Operations Center collector registration and communication by entering the following:

`example-oc> show tunclient`  
`Client configured: Yes`  
`Server: 172.23.27.182`  
`Proto: tcp`  
`Port: 443`  
`Cipher: AES-128-CBC`  
`Compression: On`  
`Tunnel Server IP: 5.0.0.1`  
`Tunnel Client IP: 5.0.0.10`  
`Server reachable: Yes`  
`Service running: Yes`  
`Latest Service Log Entries:`  
`Apr 10 17:02:51 localhost openvpn[20804]: VERIFY KU OK`  
`Apr 10 17:02:51 localhost openvpn[20804]: Validating certificate extended key usage`  
`Apr 10 17:02:51 localhost openvpn[20804]: ++ Certificate has EKU (str) TLS Web Server Authentication, expects TLS Web Server Authentication`  
`Apr 10 17:02:51 localhost openvpn[20804]: VERIFY EKU OK`  
`Apr 10 17:02:51 localhost openvpn[20804]: VERIFY OK: depth=0, /C=US/ST=CA/L=Santa_Clara/O=Infoblox/OU=na_Operations_Center/CN=OC182/name=Tunnel-Server/emailAddress=support@infoblox.com`  
`Apr 10 17:02:51 localhost openvpn[20804]: Data Channel Encrypt: Cipher 'AES-128-CBC' initialized with 128 bit key`  
`Apr 10 17:02:51 localhost openvpn[20804]: Data Channel Encrypt: Using 160 bit message hash 'SHA1' for HMAC authentication`  
`Apr 10 17:02:51 localhost openvpn[20804]: Data Channel Decrypt: Cipher 'AES-128-CBC' initialized with 128 bit key`  
`Apr 10 17:02:51 localhost openvpn[20804]: Data Channel Decrypt: Using 160 bit message hash 'SHA1' for HMAC authentication`  
`Apr 10 17:02:51 localhost openvpn[20804]: Control Channel: TLSv1, cipher TLSv1/SSLv3 DHE-RSA-AES256-SHA, 1024 bit RSA`  
`example-oc>`

14. Log back in to the Standby Operations Center UI. In **Settings** **–>** **Setup** **–>** **Tunnels** **and** **Collectors**, verify that each of the registered collectors are online. The Operations Center will begin receiving data from collectors immediately after connection is established. Data processing and analysis will catch up in a time interval similar to how long the collectors were offline.

15. In **Settings****–>**** Database ****Settings ****–>**** Scheduled**** Archive**, define the new archiving settings that you will need for the new Operations Center system, including enabling automatic archiving, defining the recurrence pattern, and defining the remote systems that will receive the periodic archives.

## > Macro (anchor)

> Macro (anchor)

Replacing a Collector

Prerequisites:

Prepare a new collector (that is, the replacement collector) that will replace the existing one, including:

- Configure the management port IP address on the replacement collector using the Admin Shell with SSH and the following command:  
`new_collector_admin > ``configure server`

- Install the standalone license on the replacement collector. For more information, see [<span style="color: #0000ff">*5th Step: Installing the Operations Center Collector License(s)*</span>](https://infoblox-docs.atlassian.net/wiki/pages/createpage.action?spaceKey=nmri743ag&title=bookmark904&linkCreation=true&fromPageId=27984002).

To replace a collector in an Operations Center environment, complete the following:

1. On the Operations Center, go to **Settings ****–> ****Setup ****–>****Tunnels ****and ****Collectors**.
2. For the collector to be replaced, click **Actions** **–>** **Collector ****Replacement**.
3. Change the serial number of the existing collector to that of the replacement collector.
4. Click **OK**.
5. Log in to the existing collector and deregister it.  
`old_collector_admin > ``deregister`
6. Register the replacement collector to the Operations Center IP Address, and define the Operations Center Network to which the collector belongs.  
  
`new_collector_admin > ``configure tunclient`  
`NOTICE: The inactivity timeout is being disabled temporarily while this command is run.`  
`+++ Configuring Tunnel Registration Settings`  
`Registration Server/IP [`[example.com](http://example.com)`]: tunserver IP address or FQDN`  
`Registration protocol (http|https) [https]:`  
`Registration username: tunserver login`  
`Registration password: tunserver password`  
  
After executing the `configure tunclient` command, the Operations Center automatically pushes all previous collector settings to the replacement collector and the collector begins its normal discovery tasks.
7. On the Operations Center, go to **Settings** **–>** **Setup** **–>** **Scan Interfaces** and change the scan IP address for that of the new collector.
8. Verify that the replacement collector status is **Connected**: go to **Settings** **–>** **Setup –>** **Tunnels** **and** **Collectors** and check the **Status** column.


You can use SSH to log in the Operation Center's Admin Shell, to view a listing of the OC system and the collectors. The `show tunserver` command shows each collector's status in its listing.

---

**Note:**  Collectors contain only a single day of data at any given time; database restoration is not supported on collectors.

---

# > Macro (anchor)

> Macro (anchor)

> Macro (anchor)

Checking NetMRI Collectors Operation

---

**Note:** This information applies to NetMRI Operations Center installations only.

---

The **Tunnels ****and ****Collectors** page (Settings icon **–> ****Setup –>**** Tunnels**** and**** Collectors**) provides information about all collectors that are defined within a NetMRI Operations Center installation. A network consists of one or more Operations Center collectors. Each collector connects to the Operations Center through an encrypted tunnel.

The Status column in the table indicates a collector's status. For Operations Center collectors, the status you want to see is **Connected**.

You may change the data that appears in the **Tunnels**** and**** Collectors** table by choosing different columns of data. Useful information includes the following information:

|  |  |
| --- | --- |
| **VPN**** Address** | Lists the tunnel endpoint IP address assigned to each collector. |
| **Network**** Name** | The name of the network for the Operations Center. |
| **Connected ****From** | This is the actual administrative IP address of the collector. Indicates the actual endpoint IP address and TCP port number across which the collector is tunneling (using its associated VPN endpoint). |
| **Bytes**** Received** and **Bytes**** Sent** | Lists the total amount of data received by, and sent by, each collector during its entire active period in the OC. |

Collectors also have Licensing limits, corresponding to those described in the topic *<span style="color: #0000ff">[Understanding](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)*<span style="color: #0000ff">[Platform](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)*<span style="color: #0000ff">[Limits,](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)</span>**<span style="color: #0000ff">[Licensing](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)*<span style="color: #0000ff">[Limits](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)*<span style="color: #0000ff">[and](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)*<span style="color: #0000ff">[Effective](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)</span>*[ ](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)*<span style="color: #0000ff">[Limits](https://infoblox-docs.atlassian.net/wiki/spaces/NMRI743AG/pages/27983900)</span>*. The **Tunnels ****and ****Collectors** page lists the following information:

|  |  |
| --- | --- |
| **Device ****Limit** | Shows the maximum device license count for the collector–the number of devices the collector is licensed to manage. (This value does not apply to discovered device counts, which can be higher.) The value in this column corresponds to an Effective Device Limit for the collector. |
| **Licensed ****Devices** | The number of consumed device licenses for the listed collector. The difference between this value and the Device Limit represents the number of device licenses remaining available to the collector appliance. |

To view a collector's event logs, do the following:

1. Click the Actions icon and choose **Log ****Messages**.
2. Click **Yes** to continue.
3. When the log is available, it appears in a window.

To obtain and send technical data from any collector for troubleshooting purposes, do the following:

1. Click the Actions icon and choose **Send** **Support** **Bundle**.
2. Choose a Transfer Mode: Download to Client Workstation or Send to Infoblox Support Site.
3. Click, CTRL+click or SHIFT+click to select one or more **Data** **Categories**. Sending technical data requires at least one category selection.
4. Click **Start** and confirm the operation.